The Luxe Style 25W unit features an energy-efficient 4-pin single-ended UV lamp measuring 550 mm in length, rated for an operational lifespan of up to 8,000 hours. Operating via an electronic ballast on standard 220–240 V / 50 Hz power, it consumes 25 W of power. For electrical safety in residential and utility installations, the stainless steel reactor body is equipped with an integrated grounding terminal. With its compact profile and standard threaded connections, the system serves as a dependable biological barrier before water reaches domestic taps and distribution manifolds.
Functional Features:
253.7 nm Germicidal Disinfection: Neutralizes pathogens at the cellular level with an intensity of 77 µW/cm² without altering water taste, odor, or chemical composition.
Stainless Steel Housing: Corrosion-resistant construction fitted with a dedicated electrical grounding contact for safe operation.
Higher Flow Capacity (1.1 m³/h): Provides continuous biological protection delivering up to 1100 L/h of purified drinking water.
8,000-Hour Lamp Lifespan: Offers approximately 12 months of continuous, around-the-clock disinfection performance.
Standard 1/2" Connections: Threaded 1/2" ports integrate seamlessly with household plumbing and filtration manifolds.
Low 25 W Power Consumption: Delivers powerful, continuous microbiological protection with low daily electricity usage.
Technical Characteristics:
Product Type: Ultraviolet Water Sterilization System
Brand: Luxe Style
Lamp Wattage: 25 W
Flow Rate Capacity: 1.1 m³/h (1100 L/h)
Lamp Base / Holder: 4 Pins Single Ended
Wavelength: 253.7 nm
UV Intensity (distance = 1 m): 77 µW/cm²
Lamp Lifespan: Up to 8,000 hours
Lamp Dimensions: Length 550 mm, Diameter 15 mm
Housing Material: Stainless Steel
Maximum Working Pressure: 7 bar
Inlet/Outlet Port Size: 1/2"
Operating Voltage / Frequency: 220–240 V / 50 Hz
Working Water Temperature: +10 to +60 °C
Feed Water Turbidity Requirement: < 0.1 NTU
Maximum Total Dissolved Solids (TDS): Up to 2000 ppm
Please note: UV disinfection requires clear water to remain effective. Feed water turbidity must be below 0.1 NTU; installing a 1-micron sediment pre-filter cartridge upstream of the unit is strongly recommended. The stainless steel housing must be connected to an electrical ground. Replace the UV lamp every 12 months (8,000 hours), and periodically inspect and clean the quartz sleeve to remove mineral scale.